Technical building blocks

gtbmodbus

Modbus Catalogue

Open catalogue of Modbus devices — registers, types, scaling, RTU/TCP.

  • rtu
  • tcp
  • registers

SMA

Sunny Tripower/Boy Series Dynamic

PV inverter RTUTCP 8 registers To check

To check

  • Ordre d'octets non spécifié — défaut AB-CD, vérifier sur datasheet

Source

upstream: ha-modbus-manager · 8932e9a

Writes

0

Scaled

8

Enums

0

Multi-register

8

Registers (8/8)

scaleunit
0x7741 (30529)inputSolar Production Total · solar_production_total uint32 ×2 1WhR
0x7831 (30769)inputDC Current · dc_current uint32 ×2 0.001AR
0x7833 (30771)inputDC Voltage · dc_voltage uint32 ×2 0.001VR
0x7835 (30773)inputDC Power · dc_power uint32 ×2 1WR
0x7837 (30775)inputAC Power Total · ac_power_total uint32 ×2 1WR
0x7839 (30777)inputAC Power L1 · ac_power_l1 uint32 ×2 1WR
0x783B (30779)inputAC Power L2 · ac_power_l2 uint32 ×2 1WR
0x783D (30781)inputAC Power L3 · ac_power_l3 uint32 ×2 1WR
Calculations run locally in your browser. No data is sent to our servers.
open/gtb · MIT · hosted in France
visitors github roadmap messages contact
SYS OK 15/18 tools online uptime — Rack temp 21.3 °C