SolaX

SolaX Series Dynamic

PV inverter RTUTCP 22 registers To check

To check

  • Ordre d'octets non spécifié — défaut AB-CD, vérifier sur datasheet

Source

upstream: ha-modbus-manager · 8932e9a

Writes

4

Scaled

22

Enums

0

Multi-register

2

Registers (22/22)

scaleunit
0x0000 (0)inputPV Voltage 1 · pv_voltage_1 uint16 0.1VR
0x0000 (0)holdingExport Power Limit · export_power_limit uint16 1WR/W
0x0001 (1)inputPV Current 1 · pv_current_1 uint16 0.1AR
0x0001 (1)holdingBattery Charge Power Limit · battery_charge_power_limit uint16 1WR/W
0x0002 (2)inputPV Power 1 · pv_power_1 uint16 1WR
0x0002 (2)holdingBattery Discharge Power Limit · battery_discharge_power_limit uint16 1WR/W
0x0003 (3)inputPV Voltage 2 · pv_voltage_2 uint16 0.1VR
0x0003 (3)holdingBattery SOC Min · battery_soc_min uint16 0.1%R/W
0x0004 (4)inputPV Current 2 · pv_current_2 uint16 0.1AR
0x0005 (5)inputPV Power 2 · pv_power_2 uint16 1WR
0x0015 (21)inputGrid Voltage · grid_voltage uint16 0.1VR
0x0016 (22)inputGrid Current · grid_current int16 0.1AR
0x0017 (23)inputGrid Power · grid_power int16 1WR
0x0018 (24)inputGrid Frequency · grid_frequency uint16 0.01HzR
0x0029 (41)inputInverter Power · inverter_power uint16 1WR
0x002A (42)inputInverter Temperature · inverter_temperature int16 0.1°CR
0x003D (61)inputBattery Voltage · battery_voltage uint16 0.1VR
0x003E (62)inputBattery Current · battery_current int16 0.1AR
0x003F (63)inputBattery Power · battery_power int16 1WR
0x0040 (64)inputBattery SOC · battery_soc uint16 0.1%R
0x0051 (81)inputPV Energy Today · pv_energy_today uint32 ×2 0.1kWhR
0x0053 (83)inputPV Energy Total · pv_energy_total uint32 ×2 0.1kWhR