Onduleur PV RTU 50 registres À vérifier
À vérifier
- Source upstream : tuto tiers, vérifier les registres
- Pas de config RTU/TCP fournie en amont
- Ordre d'octets (word order) non spécifié — défaut AB-CD, vérifier sur datasheet
Registres (50/50)
| scale | unité | ||||||
|---|---|---|---|---|---|---|---|
| 0x0BCD (3021) | holding | System-time-year | uint16 | a | R | ||
| 0x0BCE (3022) | holding | System-time-month | uint16 | R | |||
| 0x0BCF (3023) | holding | System-time-day | uint16 | a | R | ||
| 0x0BD0 (3024) | holding | System-time | uint16 | R | |||
| 0x0BD1 (3025) | holding | System-time | uint16 | R | |||
| 0x0BD2 (3026) | holding | System-time-second | uint16 | R | |||
| 0x0BD4 (3028) | holding | Inverter-total-power-generation | uint32 ×2 | kW | R | ||
| 0x0BD6 (3030) | holding | Inverter-power-generation-in-the-month | uint32 ×2 | kW | R | ||
| 0x0BD8 (3032) | holding | Inverted-last-month's-power-generation | uint32 ×2 | kW | R | ||
| 0x0BDA (3034) | holding | Inverter-power-generation-today | uint16 | kW | R | ||
| 0x0BDB (3035) | holding | Inverter-yesterday's-power-generation | uint16 | kW | R | ||
| 0x0BDC (3036) | holding | Inverter-power-generation-this-year | uint32 ×2 | kW | R | ||
| 0x0BDE (3038) | holding | Inverter-last-year's-power-generation | uint32 ×2 | kW | R | ||
| 0x0BE8 (3048) | holding | Dc-voltage-1 | uint16 | V | R | ||
| 0x0BE9 (3049) | holding | Dc-current-1 | uint16 | A | R | ||
| 0x0BEA (3050) | holding | Dc-voltage-2 | uint16 | V | R | ||
| 0x0BEB (3051) | holding | Dc-current-2 | uint16 | A | R | ||
| 0x0BEC (3052) | holding | Dc-voltage-3 | uint16 | V | R | ||
| 0x0BED (3053) | holding | Dc-current-3 | uint16 | A | R | ||
| 0x0BEE (3054) | holding | Dc-voltage-4 | uint16 | V | R | ||
| 0x0BEF (3055) | holding | Dc-current-4 | uint16 | A | R | ||
| 0x0BF0 (3056) | holding | Total-dc-output-power | uint32 ×2 | W | R | ||
| 0x0BFE (3070) | holding | Dc-bus-voltage | uint16 | V | R | ||
| 0x0BFF (3071) | holding | Dc-bus-half-voltage | uint16 | V | R | ||
| 0x0C00 (3072) | holding | Ab-line-voltage-/-phase-A-voltage | uint16 | V | R | ||
| 0x0C01 (3073) | holding | Bc-line-voltage-/-phase-B-voltage | uint16 | V | R | ||
| 0x0C02 (3074) | holding | Ca-line-voltage-/-C-phase-voltage | uint16 | V | R | ||
| 0x0C03 (3075) | holding | Phase-A-current | uint16 | A | R | ||
| 0x0C04 (3076) | holding | Phase-B-current | uint16 | A | R | ||
| 0x0C05 (3077) | holding | Phase-C-current | uint16 | A | R | ||
| 0x0C06 (3078) | holding | Active-power | int32 ×2 | W | R | ||
| 0x0C0A (3082) | holding | Apparent-power | int32 ×2 | V | R | ||
| 0x0C13 (3091) | holding | National-standard | uint16 | R | |||
| 0x0C14 (3092) | holding | Inverter-temperature | uint16 | R | |||
| 0x0C15 (3093) | holding | Grid-frequency | uint16 | Hz | R | ||
| 0x0C16 (3094) | holding | Current-state-of-the-inverter | uint16 | R | |||
| 0x0C1F (3103) | holding | Actual-power | uint16 | R | |||
| 0x0C20 (3104) | holding | Actual-power | int16 | R | |||
| 0x0C2A (3114) | holding | Set-the-flag-bit | uint16 | R | |||
| 0x0C35 (3125) | holding | Electricity-meter-total-active-power-generation | uint32 ×2 | Wh | R | ||
| 0x0C37 (3127) | holding | Meter-voltage | uint16 | R | |||
| 0x0C38 (3128) | holding | Meter-current | uint16 | R | |||
| 0x0C39 (3129) | holding | Meter-active-power | int32 ×2 | R | |||
| 0x0C3B (3131) | holding | Energy-storage-control-switch | uint16 | R | |||
| 0x0C3C (3132) | holding | Battery-voltage | uint16 | V | R | ||
| 0x0C3D (3133) | holding | Battery-current | int16 | A | R | ||
| 0x0C3E (3134) | holding | Battery-current-direction | uint16 | R | |||
| 0x0C3F (3135) | holding | Llcbus-voltage | uint16 | V | R | ||
| 0x0C40 (3136) | holding | Bypassac-voltage | uint16 | V | R | ||
| 0x0C41 (3137) | holding | Bypass-ac-current | uint16 | A | R |