Briques techniques

gtbmodbus

Catalogue Modbus

Catalogue ouvert de devices Modbus — registres, types, échelles, RTU/TCP.

  • rtu
  • tcp
  • registres

schneider

electric-pm700

Compteur électrique RTU 50 registres À vérifier

À vérifier

  • Source upstream : tuto tiers, vérifier les registres
  • Pas de config RTU/TCP fournie en amont
  • Ordre d'octets (word order) non spécifié — défaut AB-CD, vérifier sur datasheet

Registres (50/50)

scaleunité
0x03E8 (1000)holdingReal-energy,-total float32 ×2 kWhR
0x03EA (1002)holdingApparent-energy,-total float32 ×2 kVAhR
0x03EC (1004)holdingReactive-energy,-total float32 ×2 kVARhR
0x03EE (1006)holdingReal-power,-total float32 ×2 kWR
0x03F0 (1008)holdingApparent-power,-total float32 ×2 kVAR
0x03F2 (1010)holdingReactive-power,-total float32 ×2 kVARR
0x03F4 (1012)holdingPower-factor,-total float32 ×2 R
0x03F6 (1014)holdingVoltage,-L-L,-3P-average float32 ×2 VoltR
0x03F8 (1016)holdingVoltage,-L-N,-3P-average float32 ×2 VoltR
0x03FA (1018)holdingCurrent,-3P-average float32 ×2 AmpR
0x03FC (1020)holdingFrequency float32 ×2 HzR
0x03FE (1022)holdingReal-power,-total-demand-present float32 ×2 kWR
0x0400 (1024)holdingApparent-power,-total-demand-present float32 ×2 kVAR
0x0402 (1026)holdingReactive-power,-total-demand-present float32 ×2 kVARR
0x0404 (1028)holdingReal-power,-total-demand-peak float32 ×2 kWR
0x0406 (1030)holdingApparent-power,-total-demand-peak float32 ×2 kVAR
0x0408 (1032)holdingReactive-power,-total-demand-peak float32 ×2 kVARR
0x040A (1034)holdingCurrent,-A float32 ×2 AmpR
0x040C (1036)holdingCurrent,-B float32 ×2 AmpR
0x040E (1038)holdingCurrent,-C float32 ×2 AmpR
0x0410 (1040)holdingCurrent,-N float32 ×2 AmpR
0x0412 (1042)holdingCurrent,-A,-demand-present float32 ×2 AmpR
0x0414 (1044)holdingCurrent,-B,-demand-present float32 ×2 AmpR
0x0416 (1046)holdingCurrent,-C,-demand-present float32 ×2 AmpR
0x0418 (1048)holdingCurrent,-A,-demand-peak float32 ×2 AmpR
0x041A (1050)holdingCurrent,-B,-demand-peak float32 ×2 AmpR
0x041E (1054)holdingVoltage,-A-B float32 ×2 VoltR
0x0420 (1056)holdingVoltage,-B-C float32 ×2 VoltR
0x0422 (1058)holdingVoltage,-C-A float32 ×2 VoltR
0x0424 (1060)holdingVoltage,-A-N float32 ×2 VoltR
0x0426 (1062)holdingVoltage,-B-N float32 ×2 VoltR
0x0428 (1064)holdingVoltage,-C-N float32 ×2 VoltR
0x042A (1066)holdingReal-power,-A float32 ×2 kWR
0x042C (1068)holdingReal-power,-B float32 ×2 kWR
0x042E (1070)holdingReal-power,-C float32 ×2 kWR
0x0430 (1072)holdingApparent-power,-A float32 ×2 kVAR
0x0432 (1074)holdingApparent-power,-B float32 ×2 kVAR
0x0434 (1076)holdingApparent-power,-C float32 ×2 kVAR
0x0436 (1078)holdingReactive-power,-A float32 ×2 kVARR
0x0438 (1080)holdingReactive-power,-B float32 ×2 kVARR
0x043A (1082)holdingReactive-power,-C float32 ×2 kVARR
0x043C (1084)holdingCurrent,-A,-THD float32 ×2 %R
0x043E (1086)holdingCurrent,-B,-THD float32 ×2 %R
0x0440 (1088)holdingCurrent,-C,-THD float32 ×2 %R
0x0444 (1092)holdingVoltage,-A-N,-THD float32 ×2 %R
0x0446 (1094)holdingVoltage,-B-N,-THD float32 ×2 %R
0x0448 (1096)holdingVoltage,-C-N,-THD float32 ×2 %R
0x044A (1098)holdingVoltage,-A-B,-THD float32 ×2 %R
0x044C (1100)holdingVoltage,-B-C,-THD float32 ×2 %R
0x044E (1102)holdingVoltage,-C-A,-THD float32 ×2 %R

Source

upstream : jibrilsharafi · fba9d46

doc d'origine

Calculs effectués localement dans votre navigateur. Aucune donnée envoyée sur nos serveurs.