Briques techniques

gtbmodbus

Catalogue Modbus

Catalogue ouvert de devices Modbus — registres, types, échelles, RTU/TCP.

  • rtu
  • tcp
  • registres

schneider

electric-symmetra-px

Autre RTU 50 registres À vérifier

À vérifier

  • Source upstream : tuto tiers, vérifier les registres
  • Pas de config RTU/TCP fournie en amont

Registres (50/50)

scaleunité
0x0001 (1)holdingAlarm/Status-register uint16 R
0x0002 (2)holdingAlarm/Status-register uint16 R
0x0003 (3)holdingAlarm/Status-register uint16 R
0x0004 (4)holdingAlarm/Status-register uint16 R
0x0005 (5)holdingAlarm/Status-register uint16 R
0x0006 (6)holdingLine-quality-00FF=acceptable-utility-line-quality-0000=unacceptable-utility-line-quality uint16 R
0x0007 (7)holding%-battery-capacity-remaining-battery-capacity-as-a-percent-of-the-fully-charged-condition-(0-100) uint16 %R
0x0008 (8)holdingRuntime-remaining uint16 minutesR
0x0009 (9)holdingBattery-voltage-present-UPS-battery-voltage uint16 VR
0x000A (10)holdingUPS-internal-temperature-(0-209)-00XX=valid-reading-FFXX=invalid-reading-XX=sensor-reading uint16 DCR
0x000B (11)holdingAmps-drawn-by-load uint16 AR
0x000C (12)holdingNumber-of-battery-packs-with-bad-batteries uint16 eachR
0x000D (13)holdingNumber-of-battery-packs uint16 eachR
0x000E (14)holdingUPS-output-load-as-a-percentage-of-full-rated-load-in-watts uint16 %R
0x000F (15)holdingMaximum-input-voltage-since-last-reading uint16 VR
0x0010 (16)holdingMinimum-input-voltage-since-last-reading uint16 VR
0x0011 (17)holdingNominal-battery-voltage uint16 VR
0x0012 (18)holdingActual-battery-voltage uint16 VR
0x0013 (19)holdingUtility-input-frequency uint16 HzR
0x0014 (20)holdingPhase-A-utility-input-voltage uint16 VR
0x0015 (21)holdingPhase-A-utility-input-current uint16 AR
0x0016 (22)holdingPhase-A-bypass-input-voltage uint16 VR
0x0017 (23)holdingPhase-A-percent-of-maximum-output-VA-@-N-+-0 uint16 %R
0x0018 (24)holdingPhase-A-percent-of-maximum-output-VA-@-N-+-x uint16 %R
0x0019 (25)holdingPhase-A-output uint16 kVAR
0x001A (26)holdingPhase-A-output-voltage uint16 VR
0x001B (27)holdingPhase-A-output-current uint16 AR
0x001C (28)holdingPhase-A-peak-output-current uint16 AR
0x001D (29)holdingPhase-B-utility-input-voltage uint16 VR
0x001E (30)holdingPhase-B-utility-input-current uint16 AR
0x001F (31)holdingPhase-B-bypass-input-voltage uint16 VR
0x0020 (32)holdingPhase-B-percent-of-maximum-output-VA-@-N-+-0 uint16 %R
0x0021 (33)holdingPhase-B-percent-of-maximum-output-VA-@-N-+-x uint16 %R
0x0022 (34)holdingPhase-B-output uint16 kVAR
0x0023 (35)holdingPhase-B-output-voltage uint16 VR
0x0024 (36)holdingPhase-B-output-current uint16 AR
0x0025 (37)holdingPhase-B-peak-output-current uint16 AR
0x0026 (38)holdingPhase-C-utility-input-voltage uint16 VR
0x0027 (39)holdingPhase-C-utility-input-current uint16 AR
0x0028 (40)holdingPhase-C-bypass-input-voltage uint16 VR
0x0029 (41)holdingPhase-C-percent-of-maximum-output-VA-@-N-+-0 uint16 %R
0x002A (42)holdingPhase-C-percent-of-maximum-output-VA-@-N-+-x uint16 %R
0x002B (43)holdingPhase-C-output uint16 kVAR
0x002C (44)holdingPhase-C-output-voltage uint16 VR
0x002D (45)holdingPhase-C-output-current uint16 AR
0x002E (46)holdingPhase-C-peak-output-current uint16 AR
0x002F (47)holdingEnvironmental-monitoring-card-temperature-reading-(Sensor-1) uint16 DCR
0x0030 (48)holdingEnvironmental-monitoring-card-humidity-reading-(Sensor-1) uint16 %RHR
0x0031 (49)holdingEnvironmental-monitoring-card-temperature-reading-(Sensor-2) uint16 DCR
0x0032 (50)holdingEnvironmental-monitoring-card-humidity-reading-(Sensor-2) uint16 %RHR

Source

upstream : jibrilsharafi · fba9d46

doc d'origine

Calculs effectués localement dans votre navigateur. Aucune donnée envoyée sur nos serveurs.