solarx

power-hybrid-x1-hybrid-x3-x1ac

Onduleur PV RTU 50 registres À vérifier

À vérifier

  • Source upstream : tuto tiers, vérifier les registres
  • Pas de config RTU/TCP fournie en amont
  • Ordre d'octets (word order) non spécifié — défaut AB-CD, vérifier sur datasheet

Registres (50/50)

scaleunité
0x0001 (1)holdingGrid-current-(X1) int16 VR
0x0002 (2)holdingGrid-power-(X1) int16 WR
0x0003 (3)holdingPv-voltage1-(Hybrid) uint16 VR
0x0004 (4)holdingPv-voltage2-(Hybrid) uint16 VR
0x0005 (5)holdingPv-current1-(Hybrid) uint16 AR
0x0006 (6)holdingPv-current2-(Hybrid) uint16 AR
0x0007 (7)holdingGrid-frequency-(X1) uint16 HzR
0x0008 (8)holdingTemperature int16 R
0x0009 (9)holdingRun-mode uint16 R
0x000A (10)holdingPowerdc1-(Hybrid) uint16 WR
0x000B (11)holdingPowerdc2-(Hybrid) uint16 WR
0x000C (12)holdingTemper-fault-value int16 R
0x000D (13)holdingPv1Volt-fault-value uint16 VR
0x000E (14)holdingPv2Volt-fault-value uint16 VR
0x000F (15)holdingGfci-fault-value uint16 mAR
0x0010 (16)holdingGrid-volt-fault-value uint16 VR
0x0011 (17)holdingGrid-freq-fault-value-T uint16 HzR
0x0012 (18)holdingDci-fault-value uint16 mAR
0x0013 (19)holdingTime-count-down uint16 msR
0x0014 (20)holdingBat-voltage-charge1 int16 VR
0x0015 (21)holdingBat-current-charge1 int16 AR
0x0016 (22)holdingBatpower-charge1 int16 WR
0x0017 (23)holdingBMS-connect-state uint16 R
0x0018 (24)holdingTemperature-bat int16 R
0x001C (28)holdingBattery-capacity uint16 %R
0x001D (29)holdingOutput-energy-Charge.LSB uint16 KWhR
0x001E (30)holdingOutput-energy-Charge.MSB uint16 KWhR
0x001F (31)holdingBMS-warning-LSB uint16 R
0x0020 (32)holdingOutput-energy-charge-today uint16 KWhR
0x0021 (33)holdingInput-energy-Charge.LSB uint16 KWhR
0x0022 (34)holdingInput-energy-Charge.MSB uint16 KWhR
0x0023 (35)holdingInput-energy-charge-today uint16 KWhR
0x0024 (36)holdingBMS-charge-max-current uint16 AR
0x0025 (37)holdingBMS-discharge-max-current uint16 AR
0x0026 (38)holdingBMS-warning-MSB uint16 R
0x0040 (64)holdingInv-fault-Message.LSB uint16 R
0x0041 (65)holdingInv-fault-Message.MSB uint16 R
0x0043 (67)holdingMgr-fault-message uint16 R
0x0046 (70)holdingFeedin-power-(meter) int32 ×2 wR
0x0048 (72)holdingFeedin-energy-total-(meter) uint32 ×2 kwhR
0x004A (74)holdingConsum-energy-total-(meter) uint32 ×2 kwhR
0x004C (76)holdingEPS-volt-(X1) uint16 VR
0x004D (77)holdingEPS-current-(X1) uint16 AR
0x004E (78)holdingEPS-power-(X1) uint16 VAR
0x004F (79)holdingEPS-frequency-(X1) uint16 HzR
0x0050 (80)holdingEtoday-togrid uint16 kwhR
0x0052 (82)holdingEtotal-togrid uint32 ×2 kwhR
0x0054 (84)holdingLock-state uint16 R
0x0066 (102)holdingBus-volt uint16 VR
0x0067 (103)holdingW-dcv-fault-val uint16 VR