AC011E-01

Onduleur PV RTUTCP 27 registres À vérifier

À vérifier

  • Ordre d'octets non spécifié — défaut AB-CD, vérifier sur datasheet

Registres (27/27)

scaleunité
0x52D2 (21202)holdingOutput Current · output_current uint16 0.1AR/W
0x52D3 (21203)holdingPhase Mode · phase_mode uint16 R/W
0x52DA (21210)holdingCharger Enable · charger_enable uint16 R/W
0x52DB (21211)holdingRemote Control · remote_control uint16 R
0x52DB (21211)holdingStart Charging · start_charging uint16 R/W
0x52DB (21211)holdingStop Charging · stop_charging uint16 R/W
0x52E7 (21223)inputDevice Type Code · device_type_code uint16 R
0x52E8 (21224)inputPower Phases · power_phases uint16 R
0x52EF (21231)holdingMileage per kWh · mileage_per_kwh_set uint16 0.1km/kWhR/W
0x530D (21261)inputRated Voltage · rated_voltage uint16 VR
0x530E (21262)holdingWorking Mode · working_mode uint16 R/W
0x5315 (21269)inputPhase Switching Status · phase_switching_status_raw uint16 R
0x5317 (21271)inputMinimum Charging Power · minimum_charging_power uint16 1WR
0x5318 (21272)inputMaximum Charging Power · maximum_charging_power uint16 1WR
0x5333 (21299)inputTotal Energy · total_energy uint32 ×2 1WhR
0x5335 (21301)inputPhase A Charging Voltage · phase_a_charging_voltage uint16 0.1VR
0x5336 (21302)inputPhase A Charging Current · phase_a_charging_current uint16 0.1AR
0x5337 (21303)inputPhase B Charging Voltage · phase_b_charging_voltage uint16 0.1VR
0x5338 (21304)inputPhase B Charging Current · phase_b_charging_current uint16 0.1AR
0x5339 (21305)inputPhase C Charging Voltage · phase_c_charging_voltage uint16 0.1VR
0x533A (21306)inputPhase C Charging Current · phase_c_charging_current uint16 0.1AR
0x533B (21307)inputCharging Power · charging_power uint32 ×2 WR
0x533D (21309)inputCharging Energy · charging_energy uint32 ×2 1WhR
0x5341 (21313)inputStart Mode · start_mode_raw uint16 R
0x5344 (21316)inputCharging Status · charging_status_raw uint16 R
0x5345 (21317)inputCharging Start Time · charging_start_time_raw uint32 ×2 R
0x5347 (21319)inputCharging End Time · charging_end_time_raw uint32 ×2 R