Briques techniques
gtbmodbus
Catalogue Modbus
Catalogue ouvert de devices Modbus — registres, types, échelles, RTU/TCP.
- rtu
- tcp
- registres
Compleo
eBox Professional
Compteur électrique RTUTCP 36 registres À vérifier
À vérifier
- Ordre d'octets non spécifié — défaut AB-CD, vérifier sur datasheet
Registres (36/36)
| scale | unité | ||||||
|---|---|---|---|---|---|---|---|
| 0x0000 (0) | input | ID · id | string | R | |||
| 0x0019 (25) | input | Serial Number · serial_number | string | R | |||
| 0x0032 (50) | input | Active Protocol · active_protocol | string | R | |||
| 0x0064 (100) | input | Manufacturer · manufacturer | string | R | |||
| 0x007D (125) | input | Platform Type · platform_type | string | R | |||
| 0x0096 (150) | input | Product Type · product_type | string | R | |||
| 0x00AF (175) | input | Modbus Table Version · modbus_table_version | uint16 | R | |||
| 0x00C8 (200) | input | Firmware · firmware | string | R | |||
| 0x00E1 (225) | input | Number Of Sockets · number_of_sockets | uint16 | R | |||
| 0x00FA (250) | input | Ocpp State · ocpp_state | uint16 | R | |||
| 0x0113 (275) | input | Status · status | string | R | |||
| 0x012C (300) | input | Cable Status · cable_status | uint16 | R | |||
| 0x012D (301) | input | Voltage Phase 1 · voltage_phase_1 | float32 ×2 | V | R | ||
| 0x012F (303) | input | Voltage Phase 2 · voltage_phase_2 | float32 ×2 | V | R | ||
| 0x0131 (305) | input | Voltage Phase 3 · voltage_phase_3 | float32 ×2 | V | R | ||
| 0x0133 (307) | input | Energy Meter Reading · energy_meter_reading | float32 ×2 | 1 | kWh | R | |
| 0x03E8 (1000) | input | Actual Max Current Phase 1 · actual_max_current_phase_1 | float32 ×2 | A | R | ||
| 0x03EA (1002) | input | Actual Max Current Phase 2 · actual_max_current_phase_2 | float32 ×2 | A | R | ||
| 0x03EC (1004) | input | Actual Max Current Phase 3 · actual_max_current_phase_3 | float32 ×2 | A | R | ||
| 0x03EE (1006) | input | Current Phase 1 · current_phase_1 | float32 ×2 | A | R | ||
| 0x03F0 (1008) | input | Current Phase 2 · current_phase_2 | float32 ×2 | A | R | ||
| 0x03F2 (1010) | input | Current Phase 3 · current_phase_3 | float32 ×2 | A | R | ||
| 0x03F4 (1012) | holding | Max Current Phase 1 · max_current_phase_1 | float32 ×2 | A | R | ||
| 0x03F4 (1012) | holding | Max Current Phase 1 · max_current_phase_1 | float32 ×2 | A | R/W | ||
| 0x03F6 (1014) | holding | Max Current Phase 2 · max_current_phase_2 | float32 ×2 | A | R | ||
| 0x03F6 (1014) | holding | Max Current Phase 2 · max_current_phase_2 | float32 ×2 | A | R/W | ||
| 0x03F8 (1016) | holding | Max Current Phase 3 · max_current_phase_3 | float32 ×2 | A | R | ||
| 0x03F8 (1016) | holding | Max Current Phase 3 · max_current_phase_3 | float32 ×2 | A | R/W | ||
| 0x03FA (1018) | holding | Fallback Max Current Phase 1 · fallback_max_current_phase_1 | float32 ×2 | A | R | ||
| 0x03FC (1020) | holding | Fallback Max Current Phase 2 · fallback_max_current_phase_2 | float32 ×2 | A | R | ||
| 0x03FE (1022) | holding | Fallback Max Current Phase 3 · fallback_max_current_phase_3 | float32 ×2 | A | R | ||
| 0x0400 (1024) | holding | Remaining Time Before Fallback · remaining_time_before_fallback | uint16 | 1 | s | R | |
| 0x0401 (1025) | holding | Station Phase Setup L1 · station_phase_setup_l1 | uint16 | R | |||
| 0x0402 (1026) | holding | Station Phase Setup L2 · station_phase_setup_l2 | uint16 | R | |||
| 0x0403 (1027) | holding | Station Phase Setup L3 · station_phase_setup_l3 | uint16 | R | |||
| 0x0404 (1028) | holding | Availability · availability | uint16 | R |
Source
upstream : ha-modbus-manager · 8932e9a